DOI Power Management Plan

In order to comply with Executive Orders 13423 and 13514 as well as DOI Power Reduction Program objectives which require bureaus to reduce the overall power consumption for workstations and laptops, the USGS will be implementing a power plan on all non-server clients beginning June 15, 2015.  A set of power schemes will be applied, by the eComputing team, to all systems through a GPO at the top level of the USGS EAD environment.
The Power Plan is designed to be as unobtrusive as possible.  It is critical that this requirement does not impact the completion of the bureau’s mission or impede day-to-day workflow.   The GPO will apply an initial Power Management Plan called “DOI Standard Power Plan” and also offer an alternative power plan called “DOI Specialized Equipment Plan”.   These power plans represent a baseline power policy.  Local Sites that require additional power settings on systems will be able to create and use their own Power management settings if the mission of their site requires an alternative plan.
For more information on on creating a Custom Power Plan please visit http://tst.usgs.gov/misc/creating-power-plans/
Contact:The Bureau Windows Technical Support Team (BWTST) gs_help_windows@usgs.gov

The tables below describes the setting for the DOI Power Management Plan:

 

DCC – DOI Power Management Plans v.3.0

When computer is: Plugged in Running on batteries
Require a password on wakeup: Yes Yes
Turn off hard disk after: After 30 minutes After 30 minutes
Sleep after: Never Never
Allow hybrid sleep: On On
Hibernate after: Never After 60 minutes
Lid close action: Do nothing Do nothing
Power button action: Shutdown Shutdown
Start menu power button: Hibernate Hibernate
Link State Power Management: Maximum power savings Maximum power savings
Minimum processor state: 5% 5%
Maximum processor state: 100% 100%
Turn off display after: After 20 minutes After 20 minutes
Adaptive display: On On
Critical battery action: Do nothing Hibernate
Low battery level: After 10 minutes After 10 minutes
Critical battery level: After 5 minutes After 5 minutes
Low battery notification: Off Off
Low battery action: Do nothing Do nothing
Common
Options
Stop processing items on this extension if an error occurs on this item No
Remove this item when it is no longer applied No
Apply once and do not reapply Yes
Power Plan (At least Windows 7) (Name: DOI Specialized Equipment Plan)
Power Plan (Windows Vista and later) (Order: 2)
Properties
Action Update
Make this the active Power Plan: Disabled
Name DOI Specialized Equipment Plan
When computer is: Plugged in Running on batteries
Require a password on wakeup: Yes Yes
Turn off hard disk after: Never Never
Sleep after: Never Never
Allow hybrid sleep: Off Off
Hibernate after: Never After 60 minutes
Lid close action: Sleep Sleep
Power button action: Shutdown Shutdown
Start menu power button: Hibernate Hibernate
Link State Power Management: Off Off
Minimum processor state: After 100 minutes After 5 minutes
Maximum processor state: After 100 minutes After 100 minutes
Turn off display after: After 15 minutes After 10 minutes
Adaptive display: On On
Critical battery action: Do nothing Hibernate
Low battery level: After 10 minutes After 10 minutes
Critical battery level: After 5 minutes After 5 minutes
Low battery notification: Off Off
Low battery action: Do nothing Do nothing
Common
Options

Stop processing items on this extension if an error occurs on this item No
Remove this item when it is no longer applied No
Apply once and do not reapply Yes
User Configuration (Disabled)
No settings defined.